Home FAQ Injection molded parts deforms

Injection molded parts deforms

 

Description

Injection molded parts that cannot be copied exactly as cavity size, some parts are torn, bent or deformed.

 

Preview

 

Causes

Possible causes

 Suggested solution

Injection molding machine Parts eject while they are too hot.

 1. Increase cooldown.

 2. Reduce melt temperature.

 3. Increase the total cycle time.

 4. Reduce mold temperature.

Mold 1. Mold sinks too deeply.

Reduce the depth of the depression, and RADIUS.

2. Apex PIN number is too small or too little.

Increasre the number of top pin diameter or.

3. The movement of the machinery is not uniform.

Check out balance and smooth nature of mechanical movement.

4. The ribs use in injection molding line or the wheel design was incorrect.

Rib used on lines, hubs and networks, such as the maximum allowable slope.

5. Mold surface finish difference.

Polish mold surface.