Possible causes
|
Recommendations to resolve
|
Injection molding machine
|
1. The sprue bushing is not aligned with the nozzle.
|
Re-link muzzle and nozzle.
|
2.Inner plastic packing too much.
|
1.Lower the injection pressure.
|
2.Reduce the screw forward time.
|
3.Jet nozzle temperature is too low.
|
Increased the jet nozzle temperature or heating an independent temperature controller.
|
4.Plastic injection is not fully cured, especially large diameter pouring sprue.
|
Increase the cooling time, but the better way is to use a smaller mouth note instead of the original.
|
Mold
|
1.Sprue bushing hole's diameter appearing hair.
|
Check if any burr, which may lead to depression. The reason of burr is sprue bushing area and noozle area have an incorrect RADIUS .
|
2.Nozzle is incorrect.
|
Rework the process of nozzle so that it has the correct RADIUS (typically 0.55m larger than the RADIUS of noozle).
|
3.Nozzle's diameter larger than the sprue aperture.
|
Install a new shoot the mouth or smaller aperture to increase injection sleeve bore diameter.
|
4.Sprue bushing lack of taper.
|
Increase the angle of the sleeve at 3 to 5 degrees.
|
5.Improper use of injection needles.
|
Check if you are using the correct type of injection needle. Wherever possible, use the inverted cone design of the injection needle or "z"-shaped needle, check the "z"-type needle is in the top-left mold in the process, "z" corner of the needle or the runner and note precede circle alone.
|
6.Poor surface accuracy.
|
Polishing internal surfaces.
|
7.Sprue bushing's diameter is too small.
|
Increase the diameter of mouth.
|